Basic Info.
Model NO.
PRW-11/100
Shape
Circle
Fusing Speed
T K
Fusing Device
Fuse Link
Standard
IEC IEEE
11
Kv
33
Kv
Transport Package
Cartons Pallets Wooden Case
Specification
IEC282-2 IEEEc37-41
Trademark
OEIpower
Origin
China Nanyang
HS Code
85351000
Production Capacity
100000
Packaging & Delivery
Package Size
600.00cm * 300.00cm * 150.00cm
Package Gross Weight
12.000kg
Product Description
CUT-OUT
Gama 20 kV a 36 kV
Gama 20 kV a 36 kV
- Circuito Principal 200 A
- Ith 8 kA.
- Montaje Vertical
- Tubo Fusible de 100 A
- Norma CEI 282-2
TYPE "OEI" "PRW" STANDARD CUTOUT DISTRIBUTION TECHNICAL SPECIFICATION - Tubo Fusible compatible con los
estándar norteamericanos.
- Este modelo permite el montaje
de la Autoválvula directamente
sobre la escuadra de fijación.
- Eslabones fusible:
de 2 Amp. a 100 Amp.
- Porcelana de color gris, efecto
Antivandálico.
-- Montaje sencillo gracias a sus
tornillos de fijación anti-giro.
- No es necesaria ninguna
herramienta para cambiar el
eslabón
La base cortacircuitos en "V" monta aisladores de columna con
armaduras metálicas externas y línea de fuga en función de los niveles
de contaminación I-III-IV asignados.
Su diseño permite el accionamiento por pértiga desde una posición mas
cómoda para la maniobra, al conseguir un ángulo de 45º con respecto a
la base de sujección.
Incorpora un tubo fusible con capacidad para eslabones de hasta 100A
, y es totalmente intercambiable con los modelos de una columna y
modelos de otros fabricantes.
El interior del tubo portafusible está constituido por un recubrimiento
vegetal lo que le confiere un poder de extinción superior a otros
modelos (según fabricante).
El Seccionalizador en "V" monta aisladores de columna con
armaduras metálicas externas y línea de fuga en función de los niveles
de contaminación I-III-IV asignados.
Su diseño permite el accionamiento por pértiga desde una posición mas
cómoda para la maniobra, al conseguir un ángulo de 45º con respecto a
la base de sujección.
Gama:
15 , 24 y 36 kV
12 - 25 - 40 - 63 -100 - 140 A
Número de Defectos: 1 , 2 (Estándar) , 3.
Tiempo de Regeneración : Min. 30s.
Principales Características :
Dispositivo Autoalimentado. Utilización conjunta con Interruptores automáticos.
Importante reducción en los costes derivados de mano de obra y sustitución de fusible de los Cut-Out
convencionales derivados de fallos transitorios, ocasionados por tormentas eléctricas , accidentes
vegetales , etc...
Ausencia de Arcos y desgaste en los contactos.
Reutilización del equipo tras su rearme manual y acoplamiento en su base.
The Fuse Cutout type DHE was developed to operate in overhead distribution systems rated at 12-15 kV and 15-27,kV or 27-38 kV grounded systems with 100 or 200 A nominal currents.
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI PRW can be applied on all three-phase system rated at or below the maximum operational rating of the cutout. In highly polluted environments or environments with high levels of salinity, a cutout may be used with a higher nominal rating than
that of the system where it is being installed, where the insulator will have a greater leakage distance to ground, allowing for
increased safety against discharge. For an even better protection against abrasions, the hardware may be supplied in stainless
steel. The fuse cutout type OEI PRW has attachment hooks in aluminum.
The Fuseholder has a stainless steel flipper, which associated with a spring doesn't allow the fuse link to be subject to traction
forces of over 3 Kgf, especially during closing. This me chanism also allows for high speed fuse link separation. The fuse cutout
type OEI PRW allows for the insertion of the fuse tube in a precise man ner and always in perfect alignment, due to the large distance
between the grunion pocket. Lower contact, silver-to-silver, provide du el current path, independent of hinge pivot. Stainless-steel
back-up springs prevent arcing when tube rises in hinge during recoil. The fuse cutout type OEI PRW may be transformed into a DICONNECT up to 300 A, by simply changing the fuse tube for an electrolytic copper blade.
The DHE Fuse Cutouts conform to ANSI and IEC standards, with independent tests performed At:
CPRI Always use quality fuse links. Only they can assure excellent performance.
Third: Specification of Cutout fuse:
- Scope of The Tender:
- General Requirements:
The cut out is fastened on a common cross arm which can be of steel, The contacts of the expulsion fuses are chosen in such a way as to ensure reliable contact pressure and drop out of the fuse carrier when operating.
The fuse carrier consist of an insulating tube into which the fuse link is built-in. The fuse link consist of a standard copper wire and a gauged silver wire as a fuse element. The fuse links are designed for standard rated current from 10A to 50A.
By its methods of operation the expulsion fuse cut outs is a switch-disconnector which breaks current within approximately 20msec and does not limit the current. After the fuse element is being melted the fuse carrier drops out from the upper fuse-base contact and performs reliable disconnection. The use carrier stays hanging on the bottom of the fuse-base contact. The operation of operator removes the fuse carrier by an insulating rod, insert a new fuse link and close it again. Expulsion fuse cutouts are applied as protection for distribution transformers and supply mains. especially for the protection against the undesired action of the short circuit current and earth fault current.
Technical data, dimensions, catalogues required.
The expulsion fuse cutouts should be supplied with the necessary element fuses rating 20A, 40A according to the approval of the client.
- Construction:
There for it should be supplied completely with fuse holder and fuse link elements with holder bimetal clamp connectors. The fuse link element shall be of a current limiting type in accordance of IEC 60282. The rating of both 33 and 11kV (24 kV insulators) fuses cutouts shall be 100A
- Short circuit interrupting ratings:
# Rated voltage (kV) | BIL (kV) | Current rating (A) |
1 24 | 145 | 100 |
2 36 | 200 | 100 |
- Standards:
/ materials covered in this specification. In case of any deviation, the vendor / manufacturer
may propose equipment / material conforming to an alternate code or standard. However, the provision of MOE standards shall supersede the provisions of these alternate standards in case of any difference.
standard | Description |
IEC 60060 | High voltage techniques |
IEC 60168 | Test on indoor and outdoor post insulator of ceramic material or glass for system with nominal voltage greater than 1000V |
IEC 60282-2 | High voltage fuses part2: Expulsion and similar insulators. |
IEC 60437 | Radio interference test on high voltage insulators |
IEC 60507 | Artificial pollution test on high voltage insulators to be used on A.C system |
ANSI C 37.41 | design tests for high voltage fuses, distribution including air switches, fuse disconnecting switches and accessories. |
ANSI C 37.42 | Specification for distribution cut outs and fuse links |
NEMA S.G 2 | High voltage fuses |
- Minimum Dielectric withstand values
Power frequency withstand 1 min Dry and wet | ||
- To earth and between poles | 24,33 kV | 50, 70 kV |
- across the isolating distance | 24, 33 | 60,80 kV |
Impulse (1.2×50µ sec) | ||
- To earth and between poles | 24 , 33 kV | 145 / 170kV |
- across the isolating distance | 24 , 33 kV | 145 , 200 kV |
- Fuse tube:
- Main assembly construction:
- Mounting arrangement:
- contacts:
each side. Embossed surfaces with wiping action are preferred. top and bottom contacts, sub assembled and mounting fitting shall be putted into the porcelain insulators. The upper fixed contacts assembly shall not be corroded when exposed to atmosphere. Upper contacts shall positively latch in the closed position. The lower contacts shall be with stainless steel backup spring to prevent arcing that may occur as the fuse tube rises slightly in the hinge operation.
- Terminals:
- Insulators:
- Load break switch:
- Galvanization:
- Deviations
- Marking:
- rated voltage
- max. continuous current rating
- rated interrupting current symmetrical
- basic insulation level
- year of manufacturing.
- Country of origin
- Technical data:
- The tenderer should fill technical data table with quotation. in addition to data schaduals,
- Details dimentions and drawings should be submitted.
- reference list should be attached with the tender.
- type test reports.
Technical data schedule 24kV Expulsion fuse cut out
# | Description | unit | required data | offered data |
1 | system voltage | kV | 24 | |
2 | Max design voltage | kV | 24 | |
3 | continuous current capacity | A | 100 | |
4 | Interrupted current (symmetrical) | kV | 8 | |
5 | BIL at altitude | kV | 145 | |
6 | total minimum creepage | mm | To be filled | |
7 | power frequency with stand 1 min. dry and wet:
| kV kV | 50 60 | |
8 | Impulse (1.2µ sec):
| kV kV | 145 145 | |
9 | Max. radio interference voltage | µV | 250 | |
10 | Ambient temp. during temp. rise test | C | ||
11 | temperature rise of contacts | C | ||
12 | temperature rise of terminals | C | ||
13 | material of supporting insulators | porcelain | ||
14 | color of the insulator | Glazed brown / grey | ||
15 | manufacture of insulator
| |||
16 | type of main contacts material | |||
17 | fuse cut out with single or stand-off insulator NEMA brackets | |||
18 | cut out suitable for removal button head fuse link | |||
19 | all assemblies potted into the porcelain | |||
20 | angle of the fuse insulator to vertical | 15°-20° | ||
21 | shed to be incorporated into upper contact assembly |
22 | all current carrying parts material | copper / copper alloy | ||
23 | conductors terminals tin plated | |||
24 | contacts silver clad | |||
25 | all ferrous components galvanized | |||
26 | load break fitting | |||
27 | arc interrupted assisted by a spring operated flipper | |||
28 | the protection of fuse link from mechanical shock by latching of toggle mechanism | |||
29 | non expandable type fuse cap | |||
30 | the fuse tube marked with manufacturer, model continuous and interrupting current rating, rated voltage and date of manufacture | |||
31 | routine tests carried out on 100% of the offered items | |||
32 | type test certificates included in the tender along with complete descriptive lierature. |
- Packing and shipment:
- Manufacturer's name
- Country of origin
- MOE item number
- MOE purchase order number.
- Weight in kg.
- Handling instruction
- Voltage and current rating.
- Samples: samples and catalogues should be send with the offer.